Our product line: Sensor amplifier, data recorder, telemetry systems, PCM encoder / decoder, measuring notebook, RPM-8000 - Contact and Sensor- less Automotive RPM Measuremen, capacitive Accelerometer, Software for transfer, display and analysis of measurement data's.
|
Please Visit the new Site--> www.kmt-gmbh.com Bitte besuchen sie die neue Seite --> www.kmt-gmbh.com Kraus Telemetry "Mobile data acquisition and telemetry systems" -Welcome to our Home Page- |
Our systems are designed for data acquisition, storing and analysis of strain, vibrations, displacement, chock, force, temperature and flow under extreme ruff conditions. The equipment size is very small, light and robust to easily fulfil all requirements for mobile applications. You will find our different system applications in vehicles, aircraft, watercraft, earth moving machines as well as for heavy duty machinery and sports equipment developments. Our equipment is even used in the aerospace, (carrying rockets). Our customers are mainly research and test departments in the automotive, racing sports, military area and in the aviation and aerospace area |
Our product line |
|
|
|
RPM 8000 Contact and Sensor-less Automotive RPM Measuremen |
![]() |
RPM 8000-PRO Offers a discerning solution for automotive RPM measurement without an additional sensor |
Software for transfer, display and analysis of measurement data's |
|
Kraus |
Kraus Telemetry Gewerbering 9 D-83624 Otterfing - Deutschland Phone +49-8024-48737 - Fax +49-8024-5532 Email: info@kraustelemetry.com Web: www.kraustelemetry.com |
Unsere Produktgruppen
Messvertärker Mini DAT Rekorder Telemetriesystems Software PDF's - Datenblätter
(nur in Englisch) Automotiv ACC - Kapacitive Beschleunigungssensoren DAQ-Systems
- Messdatenerfassungs- Notebook KMT ist Hersteller von mobilen
Meßdatenerfassungssystemen wie Telemetrie, Meßverstärker, so wie der Meßnotebook
MC16/64 und Meßdaten & PCM Recorder,. Unsere Kunden sind Entwicklungs- und
Testabteilungen von der Fahrzeug-, der Rennsport-, der Maschinenbau Industrie,
der Luft- und Raumfahrt Industrie so wie militärische Erprobungsstellen.
Meßverstärker PSC16 Komfortabler Computerprogrammierbarer (RS232) 16 Kanal
Meßverstärker für DMS, LVDT, Thermo, F/V Konferter, ISO, ICP .... Verstärkung 1
bis zu 2000 in 1er Stufen programmierbar Sensorspeisung programmierbar 4V, 8V
Automatischer Nullabgleich bis zu 4 Meßverstärker mit einer Schnittstelle
programmierbar (64 Kanäle) Ausgang +/- 5V über BNC Eingang über 9 poligen Cannon
Stecker Verschiedene Setups auf E-PROM speicherbar Stromversorgung 9-18 oder
18-32 V DC SC-4M 4 Kanal Meßverstärker für DMS, LVDT, Thermo, F/V Konferter,
ISO, ICP .... Verstärkung 10 - 100 -1000 über Steckbrücken programmierbar
Sensorspeisung über Steckbrücken programmierbar 4V, 8V Nullabgleich über Poti
Ausgang +/- 5V über BNC Eingang über 9 poligen Cannon Stecker Stromversorgung
9-18 oder 18-32 V DC C8-STG (DMS) 8 Kanal DMS Verstärker mit automatischen
Nullabgleich Verstärkung 10 - 100 -1000 über Steckbrücken programmierbar
Sensorspeisung über Steckbrücken programmierbar 4V, 8V Ausgang max. +/-10V über
BNC Eingang über 6 poligen Lemo Stecker Stromversorgung10-30 V DC KMT ist
Hersteller von mobilen Meßdatenerfassungssystemen wie Telemetrie, Meßverstärker,
so wie der Meßnotebook MC16/64 und Meßdaten & PCM Recorder. Unsere Kunden sind
Entwicklungs- und Testabteilungen von der Fahrzeug-, der Rennsport-, der
Maschinenbau Industrie, der Luft- und Raumfahrt Industrie so wie militärische
Erprobungsstellen. Datenrekorder D-2/4 4 Kanal Mini Rekorder für 2-4 Meßkanäle
mit zusätzlichem TTL Kanal Signalbandbreite im 2 Kanalbetrieb 16000 Hz per Kanal
Signalbandbreite im 4 Kanalbetrieb 8000 Hz per Kanal Simultane Abtastung, 12 bit
Auflösung, Anit- Aliasingfilter mit 8. pol. Butterworth, 3 Stunden
Aufzeichnungszeit, Computer Interfaceschnittstelle Datum-, Uhrzeitregestrieung,
Sprachkommentaraufzeichnung D-2/8 16 Kanal Mini Rekorder für 2-4-8 Meßkanäle mit
zusätzlichem TTL Kanal Signalbandbreite im 2 Kanalbetrieb 16000 Hz per Kanal
Signalbandbreite im 4 Kanalbetrieb 8000 Hz per Kanal Signalbandbreite im 8
Kanalbetrieb 4000 Hz per Kanal Simultane Abtastung, 12 bit Auflösung, Anit-
Aliasingfilter mit 8. pol. Butterworth, 3 Stunden Aufzeichnungszeit, Computer
Interfaceschnittstelle Datum-, Uhrzeitregestrieung, Sprachkommentaraufzeichnung
D-2/16 16 Kanal Mini Rekorder für 2-4-8-16 Meßkanäle mit zusätzlichem TTL Kanal
Signalbandbreite im 2 Kanalbetrieb 16000 Hz per Kanal Signalbandbreite im 4
Kanalbetrieb 8000 Hz per Kanal Signalbandbreite im 8 Kanalbetrieb 4000 Hz per
Kanal Signalbandbreite im 16 Kanalbetrieb 2000 Hz per Kanal Simultane Abtastung,
12 bit Auflösung, Anit- Aliasingfilter mit 8. pol. Butterworth, 3 Stunden
Aufzeichnungszeit, Computer Interfaceschnittstelle Datum-, Uhrzeitregestrieung,
Sprachkommentaraufzeichnung DA-PCM HS High Speed PCM Daten Recorder 1280 kbit/s
TTL 3 Stunden Aufzeichnungszeit, Datum-, Uhrzeitregestrieung,
Sprachkommentaraufzeichnung Wir haben uns spezialisiert auf mobile
Meßdatenerfassungssysteme. Unsere Kunden sind Entwicklungs- und Testabteilungen
von Fahrzeug-, Rennsport-, und Maschinenbau Industrie, sowie Luft- und Raumfahrt
Industrie als auch militärische Erprobungsstellen. Telemetrie Systeme CT8 Neu (
optional 16 Kanäle ) Kompaktes Telemetriesystem für 8 Kanäle mit direkt
Sensoranschluss . 8 Kanäle, 12 bit Auflösung, simultane Abtastung aller Kanäle ·
Antialiasing Filter · Direkt Anschluss von Sensoren (DMS, Th K, Volteingange
+/-5 od. +/-10, ICP · +/-5V analog Ausgang am Empfänger, optional auch Interface
Anschluss für PC · Übertragungsreichweite bei Sichtverbindung ca. 500m ·
Beschleunigungsfest Statisch 100g in allen Richtungen · Signalbandbreite 8 x
0...95Hz mit 40kbit Sender, 8 x 0...750Hz mit 320kbit Sender CT4-Wheel Neu (
optional 8 Kanäle) Rad- Telemetriesystem zur Übertragung von Messwerten an
Rädern · Direkt Anschluss von Sensoren (DMS, Th K, Poti, Volteingange +/-5 od.
+/-10, ICP) · Signalbandbreite 4 x 0...190Hz · Integrierte Batterie (Akku) für
ca. 12 Stunden Arbeitszeit · Digitale Übertragung im 433 MHz Band (433.3, 433.7,
434.1 or 434.5 MHz) · Es können bis zu 4 Systeme gleichzeitig betrieben werden ·
Reichweite ca. 50m bei Sichtverbindung · Wassergeschütztes Gehäuse (IP65) CT8
Rotate - Neu Telemetriesystem zur Übertragung von Messwerten von rotierenden
Teilen · Direkt Anschluss von Sensoren (DMS, Th K, Poti, Volteingange +/-5 od.
+/-10, ICP) · Signalbandbreite 8 x 0...95Hz · Integrierte Batterie (Akku) für
ca. 6 Stunden Arbeitszeit · Digitale Übertragung im 433 MHz Band (433.3, 433.7,
434.1 or 434.5 MHz) · Es können bis zu 4 Systeme gleichzeitig betrieben werden ·
Reichweite ca. 250m bei Sichtverbindung · Wassergeschütztes Gehäuse (IP65) MT32
Neu, für rotierende Anwendungen Mini Telemetriesystem für bis zu 32 Kanäle mit
direkt Sensoranschluss . bis 32 Kanäle, 12 bit Auflösung, simultane Abtastung
aller Kanäle · Antialiasing Filter · Direkt Anschluss von Sensoren (DMS, Th K,
Volteingange +/-5 od. +/-10, ICP · +/-5V analog Ausgang am Empfänger, optional
auch Interface Anschluss für PC · Beschleunigungsfest Statisch 1000g in allen
Richtungen (nur für Sendeeinheit) TEL 32/16/8 Telemetrie Telemetriesystem für 32
Meßkanäle Feste Signalbandbreite von 800Hz / Kanal mit 2,45 GHz Sender - 1,28
Mbit order Feste Signalbandbreite von 200Hz / Kanal mit 433 MHz Sender - 320
kbit order Feste Signalbandbreite von 25Hz / Kanal mit 433 MHz Sender - 40 kbit
Telemetriesystem für 16 Meßkanäle Feste Signalbandbreite von 1600Hz / Kanal mit
2,45 GHz Sender - 1,28 Mbit order Feste Signalbandbreite von 400Hz / Kanal mit
433 MHz Sender - 320 kbit order Feste Signalbandbreite von 50Hz / Kanal mit 433
MHz Sender - 40 kbit Telemetriesystem für 8 Meßkanäle Feste Signalbandbreite von
3200Hz / Kanal mit 2,45 GHz Sender - 1,28 Mbit order Feste Signalbandbreite von
800Hz / Kanal mit 433 MHz Sender - 320 kbit order Feste Signalbandbreite von
100Hz / Kanal mit 433 MHz Sender - 40 kbit Simultane Abtastung, 12 bit
Auflösung, Anit- Aliasingfilter mit 8. pol. Butterworth, Übertragungsreichweite
bei Sichtverbindung bis zu 500m (größere Reichweiten auf Anfrage) Optional auch
64 oder 128 Kanäle möglich!! PCM 4 Telemetrie Spezial 4 Kanal Mini
Telemetriesystem für 2-4 Meßkanäle mit zusätzlichem TTL Kanal Signalbandbreite
im 2 Kanalbetrieb 10000 Hz per Kanal Signalbandbreite im 4 Kanalbetrieb 5000 Hz
per Kanal Simultane Abtastung, 12 bit Auflösung, Anit- Aliasingfilter mit 8.
pol. Butterworth, Sende Frequenz 2,45 GHz, Sendeleistung 20mW mit Allgemeine
Postzulassung, Übertragungsreichweite bei Sichtverbindung bis zu 500m. Bei
schwierigen Sendeumgebungen (Interferenzen) kann Optional auch ein Diversity
Empfänger eingesetzt werden. PCM 16 Telemetrie Spezial 16 Kanal Mini
Telemetriesystem für 2-4-8-16 Meßkanäle mit zusätzlichem TTL Kanal
Signalbandbreite im 2 Kanalbetrieb 10000 Hz per Kanal Signalbandbreite im 16
Kanalbetrieb 1250 Hz per Kanal Simultane Abtastung, 12 bit Auflösung, Anit-
Aliasingfilter mit 8. pol. Butterworth, Sende Frequenz 2,45 GHz, Sendeleistung
20mW mit Allgemeine Postzulassung, Übertragungsreichweite bei Sichtverbindung
bis zu 500m. Bei schwierigen Sendeumgebungen (Interferenzen) kann Optional auch
ein Diversity Empfänger eingesetzt werden. TEL1/40k TTL 1 Kanal Telemetrie zur
Übertragung von 4 ... 40000 TTL Impulse/s Sende Frequenz 433 MHz, Sendeleistung
10mW mit Allgemeine Postzulassung, Übertragungsreichweite bei Sichtverbindung
bis zu 300m (opt. 1 km mit spezieller Empfangsantenne +8 dB) TEL1-FM - Neu 1-
Kanal Telemetrie zur DMS- Messungen auf rotierenden Wellen Signalbandbreite
0-10000Hz RTSE600 1 Kanal Mini Telemetrie mit Signalaufbereitung für DMS, LVDT
oder Thermo Sensoren. Zur berührungslosen Übertragung von rotierenden Teilen
oder Wellen Signalbandbreite 600 Hz, 12 bit Auflösung, Sende Frequenz 433 MHz,
Sendeleistung 10mW mit Allgemeine Postzulassung, Übertragungsreichweite bei
Sichtverbindung bis zu 250m Temptel 1200-14 - Spezialapplikation Spezial
Telemetriesystem zur Übertragung von 14 Temperaturkanälen aus dem Inneren eines
Bennofens bei 1200 °C/1h, wie er z.B. in der Keramikindustrie zu finden ist.
Sende Frequenz 433 MHz, Sendeleistung 10mW mit Allgemeine Postzulassung, Bei
schwierigen Sendeumgebungen (Interferenzen) kann Optional auch ein Diversity
Empfänger eingesetzt werden. Auswertesoftware µ-Edition zur Meßdaten- Erfassung,
Darstellung und Auswertung sowie für Frequenzanalyse, Klassierung,... Software:
µ-Lab und µ-Graph Erfassen und Auswerten mit 32-bit Power unter Win95 oder WinNT
Mit der brandneuen µ-Edition ist nun ein Softwarepaket von KMT & CAESAR für die
komfortable Meßdaten Erfassung und Auswertung speziell unter Windows95 und
WindowsNT verfügbar. Die Programm-Module µ-Lab und µ-Graph nutzten dabei
konsequent die 32-bit-Fähigkeiten dieser Betriebssysteme aus und bieten daher
eine im PC-Bereich bisher unerreichte Leistungsfähigkeit bei gleichzeitig
einfachster Bedienung µ-Lab ermöglicht die Erfassung, Online-Verarbeitung,
Darstellung, und Wiedergabe einer beliebigen Anzahl von Analog- und
Digitalkanälen. Hardwareseitig werden Datenerfassungs- und Ausgabekarten
namhafter Hersteller sowie natürlich der MOPS und auch PCM-Systeme unterstützt.
Die Bandbreite der Abtastrate reicht dabei von unter 1 Hz bis über 100 kHz
(kontinuierlich) bzw. 500 kHz (Burst) in Abhängigkeit von der jeweils
eingesetzten Hardware. Die erfaßten Kanäle können auf beliebig viele Dateien
verteilt werden. Bereits die Basisversion von µ-Lab beinhaltet umfangreiche
Triggerfunktionen sowie Aktionsmodule für die Grenzwertüberwachung,
Zeitsteuerung, Datenreduktion und variable Glättungsalgorithmen. Jeder Kanal
kann wahlweise linear oder nichtlinear kalibriert werden. Die Online-Grafik
erlaubt die parallele Darstellung einer unbegrenzten Anzahl grafischer Objekte:
z.B. Linienschriebe ( inkl. Scroll- und Scope-Modus), XY-Diagramme,
Balkendiagramme, Zahlenfelder oder Schalter. Jedes Objekt läßt sich hinsichtlich
seiner Eigenschafen - wie z.B. Achsenskalierung, Farben, Textfonts- individuell
definieren. Die Funktionalität der Basisversion kann optional durch
Ergänzungsmodule, z.B. für Online-Berechnungen, DIN- und Rainflow-Klassierung,
Frequenzanalyse und Sollwertvorgabe, erweitert werden. µ-Graph ist ein flexibles
grafisches Auswerteprogramm für Meßdaten aller Art. Es vereint die Funktionen
Quicklook, interaktives Arbeiten, Datenverwaltung, Präsentationsgrafik,
Statistik, Formelgenerator sowie optional Frequenzanalyse und Klassierung unter
einer besonders leicht zu bedienenden Oberfläche. Die Auswertung erfolgt einfach
durch "Ziehen" (Drag & Drop) der markierten Datensätze auf eine entsprechende
Schaltfläche in einer Symbolleiste ( z.B. Ausdrucken oder FFT ).
Selbstverständlich ist µ-Graph voll kompatibel zum REMUS-Datenformat. Ein
besonderes Highlight ist die superschnelle Quicklook-Funktion, mit deren Hilfe
auch größte Datensätze in Sekundenschnelle gesichtet werden können: Einfach den
Datensatznamen antippen und schon erscheinen selbst mehrere Mbyte Meßwerte
einschließlich der wichtigsten statistischen Kennwerte ohne erkennbare
Verzögerung auf dem Bildschirm. Der Quicklook bietet aber noch mehr: Mit Hilfe
der Maus kann ein beliebiger Datenbereich markiert und wahlweise gedruckt oder
ins Cursor-Display übernommen werden. Dort stehen dann umfangreiche interaktive
Funktionen, wie z.B. Zeit-, Fadenkreuz- und Differenz-Cursor, Zoomen, Scrollen,
Markieren und Beschriften zur Verfügung. Beim "Durchblättern" langer Datenreihen
kann man Lesezeichen setzen, die ein rasches Wiederauffinden bestimmter
Ereignisse ermöglichen. Jeder Datensatz kann als Linienschrieb, XY- bzw.
Balkendiagramm und/oder als Tabelle mit manueller oder Auto-Skalierung
ausgegeben werden. Für die freie Gestaltung von Protokollen und Berichten bietet
µ-Graph eine flexible Präsentationsgrafik. Neben fest eingebauten Zeichen- und
Beschriftungsfunktionen können hier über die OLE-Schnittstelle Objekte aus
anderen Windows-Programmen ( z.B. Excel oder Word ) eingebunden werden. Ein
einmal entworfenes Formblatt kann man als Vorlage ablegen und jederzeit auf
Knopfdruck wiederverwenden µGraph Grafisches Auswerteprogramm für technische
Daten. Allgemein Allgemein: Für Windows NT und Windows'95 optimiertes 32-Bit
Programm Ergonomische Bedienung durch: Drag&Drop-Funktion Kontextmenüs
Symbolleisten ToolTips Fremdsprachige Versionen - erhältlich in Englisch,
Französisch (Spanisch und Italienisch in Vorbereitung). Ausführliche
Dokumentation als Handbuch und Online-Dokumentation (PDF) Individuelle Anpassung
von Grundeinstellungen und Vorgaben Datenverwaltung Datenverwaltung: Auswertung
von beliebig großen Datendateien und folgenden Konfigurationen: Ringdateien
(Post mortem) Daten verteilt auf verschiedene Dateien Daten verteilt auf
verschiedene Festplatten Datenserver für optimierten Zugriff im Netzwerk
Hierarchische Anzeige der Daten in einem Projektbaum Aktiver QuickLook
Kommentierung von Datensätzen, Bereichen und Datenpunkten Laden einer beliebigen
Anzahl von Datensätzen Löschen einzelner Datensätze Ändern der
Datensatzeigenschaften: Datensatzname Bezeichnung Einheit Kalibrierung
(linear/nicht linear) Kommentar Einlesen von Fremdformaten: ASCII-Tabelle RMS,
DAT, DIF dBase Datensatzweise Protokollierung der Berechnungsverfahren
Zusammenfassung verschiedener Datendateien in Projekte Laden und Speichern von
Projektkonfigurationen Zuordnung von Berechnungsergebnissen zu Datensätzen
Verarbeitung von Datensätzen mit unterschiedlichen Abtastraten Datenanzeige
Interaktive Anzeige Darstellung einer beliebigen Datensatzanzahl als:
Zeit-Diagramm XY-Diagramm Balken-Diagramm Tabelle Cursorfunktionen: Zeitcursor
Fadenkreuz-Cursor Differenzcursor Interpolierte Cursorwerte bei Datensätzen mit
unterschiedlichen Abtastraten Verschiedene Zoomfunktionen: Beliebiges Vergrößern
und Verkleinern Anzeige des gesamten Datenbereiches Horizontales und vertikales
Scrollen Reaktivieren einer der letzten zehn Zoombereiche Setzen, Anspringen und
Löschen von Lesezeichen Verknüpfung von Diagrammen Skalierung der Achsen:
Manuelle Skalierung für jeden Datensatz Bereichsoptimierte Autoskalierung für
jeden Datensatz Abgleich der Skalen für alle Datensätze Darstellung von
Datensätzen mit unterschiedlichen Abtastraten Markieren und Beschriften von
Datenpunkten und Bereichen Abspeichern der Verknüpfung in der entsprechenden
Datendatei Schnelle Anzeige der Markierungen durch Anwahl im Hierarchiebaum
Darstellungsform und Druckbarkeit parametrierbar Kurvendefinition mit frei
wählbaren Farben- und Linientypen Integrierte Legenden- und Cursordatenanzeige
Präsentationen Präsentationen Berichts- und Präsentationsgrafiken mit freien
Gestaltungsmöglichkeiten Einfügen von Daten, Diagrammen und Tabellen über die
Drag&Drop-Funktion Entwurf von Vorlagen für einheitliche Formblätter
Zeichenfunktionen: Linien, Rechtecke Darstellung von Grafiken als
Hintergrundbild oder Logo Texte in beliebigen Windows-Schriftarten Datenobjekte
wie Diagramme und Tabellen Bearbeiten der Objekteigenschaften (Farben, Muster,
Inhalt) Komfortable Anordnung und Größenanpassung der Grafikobjekte Einbindung
von Objekten anderer Programme über die OLE-Schnittstelle (z.B. MS-Excel)
Einrichten der Seitenparameter Serielle Ausgabe aller Präsentationsseiten auf
den Drucker Vorschau der Präsentationsseite im Projektbaum Ausdruck Ausdruck
Direkter Ausdruck eines Datensatzes aus dem Projektbaum Ausdruck aller
Datensätze einer Datei auf einer oder mehreren Seite Ausdruck von einzelnen
Tabellen und Diagrammen. Ausdruck einzelner Präsentationsseiten Sortierte
Ausdruck aller Präsentationsseiten Berechnung Berechnungsmodul: Rechenfunktionen
mit einem oder mehreren Datensätzen Rechnen mit interpolierten Werten bei
Datensätzen mit unterschiedlichen Abtastraten Komfortable Definition der Formeln
Zuordnung des Berechnungsdatensatzes zu den Eingangsdatensätzen. Numerische und
Bool'sche Operationen: Mathematische Grundrechenarten () Trigonometrische
Funktionen Logarithmische / Exponentielle Funktionen Absolutbetrag, Runden,
Signumfunktion Konstanten (Euler e, p ) Umrechnung von Grad in RAD und umgekehrt
Statistik Statistik Statistische Kenngrößen: Minimum, Maximum, Mittelwerte,
Differenzen (X+Y), Standardabweichung Lineare Regression, Geradensteigung
Option: Einkanalige requenzanalyse Option: Einkanalige Frequenzanalyse:
Analyseverfahren: Amplitudenspektrum, Amplitudendichte, RMS-Spektrum,
Leistungsdichtespektrum (PSD). Korrelationsverfahren: Autokovarianz- und
normierte Autokorrelationsfunktion (AKF). Transformationen bis zur 17ten
Ordnung, d.h. mit über 130.000 Werten Fensterfunktionen: Rechteck, Dreieck,
Hanning, Hamming, Blackman, exact Blackman Korrektur der wichtungsbedingten
Amplitudendämpfung Spektrale Mittelung mit variablem Überlappungsgrad zwischen
0% und 99% Option: Klassierverfahren DIN 45667 Option: Klassierverfahren nach
DIN 45667: Klassierungsverfahren: Stichprobe, Verweildauer, Spitzenwert I,
Spitzenwert II, Spitzenwert III, Klassendurchgang, Spannen,
Spannenpaarverfahren. Relative und absolute Häufigkeitsdarstellung Berechnung
der Klassen- und der Summenhäufigkeit Entsprechend der Verfahren: Bezugsniveau
Hystereseeinstellungen Überrollung Option: Zusätzliche Klassierverfahren Option:
Zusätzliche Klassierverfahren Mehrkanalige Verbundklassierung
Rainflow-Klassierung µLab Komfortable Meßdatenerfassung unter Windows Allgemein
Allgemein: Für Windows NT und Windows'95 optimiertes 32-Bit Programm Erfassung
und Ausgabe einer beliebigen Anzahl von Analog- und Digitalkanälen Meßhardware:
Handelsübliche Datenerfassungs- und Ausgabekarten. Unterstützung von
Zählerkarten und externen Erfassungseinheiten. Abtastraten von der Hardware
abhängig - von < 1Hz bis zu: > 100kHz bei kontinuierlichen Messungen > 500kHz
bei Burst-Messungen Ergonomische Bedienung durch: Drag&Drop-Funktion
Kontextmenüs Symbolleisten ToolTips Fremdsprachige Versionen - erhältlich in
Englisch, Französisch (Spanisch und Italienisch in Vorbereitung). Ausführliche
Dokumentation als Handbuch und Online-Dokumentation (PDF) Individuelle Anpassung
von Grundeinstellungen und Vorgaben Kanaleigenschaften Parametrierbare
Kanaleigenschaften: Datensatzname, Bezeichnung, Einheit Kalibrierung
linear/nicht linear Kurvenglättung: Gleitender Mittelwert Gewichteter gleitender
Mittelwert Lineare Glättung Zusammenfassung von Digitalkanälen zu einem
Analogkanal Begrenzung des Wertebereichs für Ausgabekanäle Invertierung der
Digitalkanäle einzeln einstellbar Datenspeicherung Datenspeicherung: Speicherung
einer beliebigen Anzahl von Kanälen in beliebig viele Dateien Ringspeicherung
(Post mortem). Nur von der Festplattenkapazität abhängig. Speicherung über
mehrere Festplatte verteilt Meßwertgenaues Erfassen für Einzelmessungen
Serienmessungen Manuelle und automatische Namensvergabe AutoSave-Funktion gegen
Datenverlust Burst-Messungen direkt auf Festplatte Start- und Stop-Trigger, Pre-
und Post-Trigger Darstellung Grafische Darstellung Beliebig viele Grafikfenster
definierbar Grafikfenster mit einer beliebigen Anzahl von folgenden grafischen
Objekten: Zeit-Schrieb (Betriebsarten: Scrollen, Scope, Löschen) XY-Diagramm
Balkendiagramm Zahlenfelder Schalter Eingabeobjekte Texteigenschaften,
Achsenskalierung und Farben frei definierbar Aktionsmodule Aktionsmodule
Grenzwertüberwachungsmodul Timer-Modul Datenreduktion-Modul: Minimum, Maximum,
Mittelwert und Stichprobenreduktion (statisches und dynamisches Zeitfenster)
Extremwertreduktion Option: Online-Berechnung Option: Online-Berechnung:
Rechenfunktionen mit einem oder mehreren Datensätzen Komfortable Definition der
Formeln Numerische und Bool'sche Operationen: Mathematische Grundrechenarten ()
Trigonometrische Funktionen Logarithmische / Exponentielle Funktionen
Absolutbetrag, Runden, Signumfunktion Konstanten (Euler e, p ) Umrechnung von
Grad in RAD und umgekehrt Option: Aktionliste Option: Aktionliste An 'C'
angelehnte Programmiersprache Mathematischer Umfang wie im Berechnungsmodul
Schleifen- und Verzweigungskonstrukte (for, if, else ...) Spezielle Befehle für
Sollwertgenerierung Option: Klassierverfahren nach DIN 45667 Option:
Klassierverfahren nach DIN 45667: Klassierungsverfahren: Stichprobe,
Verweildauer, Spitzenwert I, Spitzenwert II, Spitzenwert III, Klassendurchgang,
Spannen, Spannenpaarverfahren. Option: Rainflow-Klassierung Option:
Rainflow-Klassierung: Option: Online-FFT Option: Online-FFT KMT-Messtechnik
Deutsch Messverstärker Übersicht PSC16 SC-4M C8-STG (DMS) Meßdatenaufzeichnungsg.
Übersicht D-2/4 D-2/8 D-2/16 DA-PCM HS Telemetriesysteme Übersicht CT8 CT4-Wheel
CT8 Rotate MT32 TEL 32 Telemetrie TEL 16 Telemetrie TEL 8 Telemetrie PCM 4
Telemetrie PCM 16 Telemetrie TEL1/40k TTL TEL1-FM RTSE600 RT8 Rotate Temptel
1200-14 Software Info PDFs Download Automotiv CL1 Telemetrie Meßlenkrad RPM 8000
RPM 8000-DC ACC Kapazitive Beschleunigungssensoren DAQ-Systems Übersicht We are
manufacturer of Measuring & PCM tape recorder, PCM telemetry system, -signal
conditioning, measuring notebook up to 64 CH. Our customers are research and
test departments in the automotive, racing sport, military area, aviation and
aerospace area. Sensor amplifier / signal conditioning units PSC16 Comfortable
16 channel signal conditioning unit, full computer programmable, Gain 1...2000
in steps of 1 with modules such as Strain gauge, LVDT, Thermocouples, F/V
converter Filter and more SC-8 Mobile sensor amplifier for 8 channel signal
conditioning unit, mixed installation practicable with modules for STG, LVDT,
ISO, THERMO, F/V, ICP, FILTER • Excitation 2 ranges by use of jumpers (4 or 8 V)
• Gain: 3 ranges by use of jumpers (10, 100 or 1000) • Auto Zero balancing of
STG • Full-, half- or quarter-bridges SC-4/M Mobile sensor amplifier for 4
channel signal conditioning unit, mixed installation practicable with modules
for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER • Excitation 2 ranges by use of
jumpers (4 or 8 V) • Gain: 3 ranges by use of jumpers (10, 100 or 1000) • Zero
balancing of STG via potentiometer • Full-, half- or quarter-bridges PSC16
amplifier Comfortable 16 channel signal conditioning unit, full computer
programmable, Gain 1...2000 in steps of 1 16 channel signal conditioning unit,
full computer programmable Gain 1..2000 in steps of 1 Signal conditioning for
straingauge, displacement, vibration, shock, temperature ... . Mixed
installation practicable Full computer programmable, up to 8 setups available in
the internal memory Gain 1..2000 in steps of 1 Excitation + 1, 2, 4 or 8 V
External and internal calibration Full, half or quarter bridges Supply voltage:
DC 10 ... 18 V or 18 ... 32 V or mains (opt.) The PSC 16 is a signal
conditioning unit with 16 slots for various plug in cards. It is preferable to
order all different cards to be flexible and able to fulfil unexpected
requirements for future measurements. You can plug in a large range of different
amplifier modules, such as strain gauges, carrier frequency, DC, frequency /
volt-converter or PT100-amplifier... Easy handling. Step I you define the setup
(sensitivity, bridge excitation, filter-frequency and so on), for each channel,
on an IBM-compatible PC or notebook. Step II you send it to the PSC 16 via RS
232. Up to 8 different setups can be stored. Step III in the car, on the
motorbike or where ever you want to measure, you switch on the power, select the
setup number and the PSC 16 is ready. You can connect it with a D2/16 via two
cables and the data can be stored on a DAT-tape. With further equipment you can
transmit the data via telemetry, or directly into a computer. Please tell us
what you want to do and we will offer you a suitable solution. Following
functions are also possible without a computer: AZ: Auto zero calibration. The
value is stored and not reset by power off. EXC: Excitation off. It is a very
useful function to separate trouble effects and true signals. CAL: Calibration.
One resistor can be plugged on the amplifier card, the value is dependent on the
bridge resistance and the sensitivity of the amplifier. The bridge completion is
also pluggable. Setup software for MS-Windows 3.11 and Win95: View's Front side
Back side Technical information: System System accuracy: 0;1% (full scale)
Operating temp. range: -10 ° C up to +50 ° C Humidity: 20 ... 90 % non
condensing Shock: 50 g in all directions Dimensions of PSC 16: 180x130x100 mm (l
x w x h) Weight: about 2,3 kg Supply voltage: DC 10 ... 18 V or 18 ... 32 V or
mains (opt.) Setup: software interactive with sensor module identification.
SC-Modules: 1 Basic unit = 16 slots, each slot = 1 SC-module (Signal
conditioning modules): SC DMS-1 Strain gauge module for full-, ½- and ¼-bridge
configuration Excitation setting per software 0-2-4-8 V, max. 70 mA, Short
circuit proof Differential DC amplifier Accuracy 0,1 % Gain 1...2000 in steps of
1 Offset setting Auto zero calibration Auto offset calibration Linearity 0,1 %
gain 1000; 0,2 % gain 2000 Output 5 V SC LVDT The LVDT module is designed for
all available displacement sensors. Programmable gain 1, 2, 5 and 10 (nonlinearity
error ±1%) Automatic zero adjustment and offset shift Sensor supply 5 kHz
sinusoidal, VA = 2.5V, 300W load Signal bandwidth 400Hz Signal output level ±5V,
Imax = 5mA Operating temperature: –40°C ... +80°C F/V module The F/V-module is
used to measure frequencies between 40Hz and 10kHz. Three programmable ranges
40Hz ... 500Hz 40Hz ... 2.5kHz 40Hz ... 10kHz Input signal range VA = 0.3 ...
10V Sinus, square and triangle wave forms Integrated output filter (2pol.
Butterworth, 3dB at 10Hz, 40dB at 100Hz) Output voltage 0 – 5V, Imax = 5mA Non
linearity error ±0.2% Offset error ±0.5% Operating temperature –40°C up ...
+80°C SC Pt 100 This module make the complete galvanic isolated signal
conditioning for the PT100 thermo resistor. The standard connection for short
distances is done with 2-wire techniques. For longer distances we recommend the
3-wire techniques. Temperature measuring range –100 to +600°C Output voltage -1
to +6V Accuracy ±1°C Nonlinearity error ±0.2% Isolation voltage max. 500V Sensor
supply IEXC = 0.25mA Output filter with 3dB at 3Hz SC Th Module for thermo
couples included cold junction compensation. Optional: Galvanic isolated
Accuracy 5 ° C Temp. range -20°C - +600°C Available for J and K thermo couples
SC ISO The ISO-module enables a galvanic input signal isolation. Input range
±10V Output range ±5V, Imax = 5mA Gain 0.5, non linearity error 0.2% Typ. offset
±20mV Signal bandwidth 20kHz Slew rate 1.5V/m s Isolation voltage 500V Input
resistance 200kW Operating temperature –40°C ... +80°C SC CURRENT The current
module is used to measure low currents. Input current 0... ±20mA Input
resistance 125W Output range ±5V, Imax = 5mA Operating temperature –40°C up to
+80°C SC-4/M - Mobile Sensor amplifier 4 channel signal conditioning unit, mixed
installation practicable with modules such as Straingauge, LVDT, Thermocouples,
F/V converter and more. Signal conditioning for straingauge, displacement,
vibration, shock, temperature .... Easy handling Mixed installation practicable,
1 up to 4 modules Per jumper selectable gain for STG and LVDT STG excitation + 4
or 8 V Full-, half- or quarter-bridges Power 9-18 or 18-32 VDC Size 140x180x25
mm Technical data SC-4/M consist of: Basic housing with motherboard for max. 4
signal conditioning modules DC/DC converter for power input of 9-18 or 18-32 VDC
Size 130x180x35 mm Weight incl. 4 signal conditioning modules 900g Signal
conditioning modules To measure: Module Description Characteristics Force,
pressure, strain, torsion, material stress STG Strain gauges Full, half, quarter
bridges in 2- and 3-wire technique (120W , 350W , 1kW ) Setable gain (10, 100,
1000) Setable bridge supply (4V, 8V) Offset calibration with potentiometer
Additive 5kHz fixed filter (2pol. Butterworth) distance LVDT Inductive distance
sensor Setable gain (1, 2, 5, 10) Sensor supply 5kHz, 2.5V Offset calibration
with potentiometer Frequency, speed by pulse frequency F/V Frequency-to-voltage
converter Setable maximum frequency (500Hz, 2.5kHz, 10kHz) Minimum frequency
40Hz Signal amplitude 0.3-10V Square, sine and triangle wave forms 10Hz output
filter (2pol. Butterworth) Acceleration, oscillation, vibrations ACC
Acceleration sensor based on STG all common sensors CAP Capacitance
accelerometer ICP Piezoelectric accelerometer Temperature THERMO Thermo wires
Type J, K (T) Measuring range from -20°C up to +600°C Gain 10mV/°C Internal cold
junction compensation Optional galvanic isolation with integrated ISO module
galvanic isolated voltage ISO Isolation amplifier Additive isolated sensor
excitation Optional 4Hz fixed filter (4pol. Butterworth) Current CUR
Current-to-voltage converter Input current 0-20mA Input impedance 125W Bridge
excitation 12V FILTER Optional filter for all modules 8th order elliptical or
linear phase frequency response, more than 2000 cut off frequencies from 10Hz to
7,5kHz available (reciprocal scaling) D-2/4 mini Rekorder Mini DAT with 4
channel for static and dynamic signals, 2 and 4 channel signal bandwidth up to
16000 Hz in 2 channel mode signal bandwidth up to 8000Hz in 4 channel mode
simultane scanning. scanning rate 96 kHz, 12 bit resolution, anti Aliasing
filter 8. order. Butterworth, 3 hour recording time, Computer Interface date-,
time registration, voice channel D-2/8 mini Rekorder Mini DAT with 8 channel for
static and dynamic signals, 2-4 and 8 channel signal bandwidth up to 16000 Hz in
2 channel mode signal bandwidth up to 8000Hz in 4 channel mode signal bandwidth
up to 4000Hz in 8 channel mode simultane scanning. scanning rate 96 kHz, 12 bit
resolution, anti Aliasing filter 8. order. Butterworth, 3 hour recording time,
Computer Interface date-, time registration, voice channel D-2/16 mini Rekorder
Mini DAT with 8 channel for static and dynamic signals, 2-4 and 8 channel signal
bandwidth up to 16000 Hz in 2 channel mode signal bandwidth up to 8000Hz in 4
channel mode signal bandwidth up to 4000Hz in 8 channel mode signal bandwidth up
to 2000Hz in 16 channel mode simultane scanning. scanning rate 96 kHz, 12 bit
resolution, anti Aliasing filter 8. order. Butterworth, 3 hour recording time,
Computer Interface date-, time registration, voice channel DA-PCM HS High Speed
PCM data Recorder 1280 kbit/s TTL 3 hour recording time, Computer Interface
date-, time registration, voice channel D-2/4 - mobile mini DAT recorder
Smallest 4 channel DAT recorder of world for record and playback form analog
signals up to 16 kHz per channel in 2 channel mode. Record and reproduce of 4
analog data channels, voice, date, time and digital signals. Extremely small and
ruggedized design and therefore multiple application areas Usable in each
position and therefore especially suitable for extreme mobile applications Very
resistant against shock and vibrations Extremely adaptable to various measuring
requests due to switchable number of channels and signal bandwidth Robust remote
control box with bargraph display Computer interface for on- and off-line Data
analysis (OPT.) Telemetry connection for computer interface for on-line data
analysis during mobile use (OPTION) Event-driven record commands Record commands
by Remote Control Automatic test number recording Fast search run in both
directions Power supply DC 10 ... 18 V or 18 ... 32V, battery (OPTION), mains
220 V AC (OPTION) The D-2/4 DAT Recorder is small and powerful. The physical
size has a major advantage over larger units. Due to the small mechanical
dimension it can be. This becomes apparent, whenever space or critical
positioning is the issue. Good examples are the cramped quarters of building and
earth-moving machines, cars and planes. The surveillance's and analysis is done
On-line. A telemetry output, connected to our RF telemetry TS/TE 2.5, transmits
the data to a computer. Concurrently, high redundancy recording of raw data
takes place within the DAT. With the aid of our REMUS Software all or single
channels can be selected and/or presented. The computer freed from the ''Data
Logging" task can now be utilized for analysis and presentation. The ''Record
Commands" can be controlled remotely. The "Record Procedure" is started and
terminated with the +5 V and 0 V levels respectively. Sometimes, especially
during long term measurements, continuous recording would be impractical. In
this case the ''Event-Driven" record control is a powerful tool. Supporting this
feature is one "Event Channel". Once an ."Event Channel" is activated, a ''Record
Procedure'' of approximately 1 minute is started. This procedure includes the
recording of the active event, time and test number. The D-2/4 DAT can convert
data from analog to digital and feed them into computer directly without
recording. For this operation the "Tape Bypass" function is used. Just as in
recording mode the analog data are filtered and digitized. The data are
transferred directly to the computer instead to tape. This is independent upon
the tape runs and records data or stays without recording. In this mode the DAT
recorder is used as PCM encoder for telemetry transmission. Another feature is
the pulse input DIG In/Out. With that feature any pulses with any sampling
relationship from 0 to 40 kHz can be recorded and reproduced. This input is very
suitable for PCM signals transmitted via RF telemetry. Data from PCM encoders,
input pulses from sensors for revolution or speed, or the recording of simple
events are just a few. Optionally an event multiplexer for 16 events is
available. These are some examples of the flexible use of our Data Recorder
D-2/4. For more information contact our sales office. References: (D-2/16 and
D-2/4) Aprilia motorcycle Italy Benetton Formula 1 England CNES France MIR Space
Sation Daewoo Corp. Korea Ferrari Formula 1 Italy Fiat Italy Renault Sport
France SAGEM France Samsung Heavy Industry Korea Hyundai Korea Military test
departments Railway Germany VW Brazil and many more .... . References: (D-2/16,
D-2/8 and D-2/4) Missile (D-2/16) Missile (D-2/4) MIR Space Station (D-2/8 Spec.)
CNES France Technical data: 4 analog channels; input and output are connected
via BNC connectors Measuring range +/-5 V with overload indication for each
channel Resolution 12 Bit, simultaneous sampling of all channels Input impedance
100 KOhm, SNR 72 dB Over voltage protection +40 V Total sampling rate 96 kHz,
distributed to selected number of channels ( see table ) 8-pole lowpass
Butterworth filter for input and output, avoiding Aliasing effects and smoothing
the output signals; damping in locking area 48 dB/Octave Analog output impedance
2 Ohme, max. 10 mA, +/-5V Programmable for 2 - 4 channel mode Signal bandwidth
max. in 2 channel mode 0 ... 16 kHz (-3dB) Serial Interface, suitable for direct
transmission even over long cables or for RF- or IR-transmission PC Interface
plug-in board for all IBM comp. PCs (Option) Digital pulse input (TTL), that
means pulses from 0 ... 40 kHz can be recorded and reproduced. Date and time
recording (year- month - day - hour - minute - second) Tape length counter for
absolute time, programming time, remaining record time. Automatic or manual
setting of test number Fast search run in both directions searching the test
number Remote control unit with bargraph display, Voice channel and overload
indication (option) Voice channel with external microphone and built-in
loudspeaker, signal bandwidth 60 ... 2800 Hz. Recording time 3 hours with a
DT180 cassette Storing capacity approximate, 2.4 Giga Byte with a DT180 cassette
Reproducible accuracy between record and replay at 0 Hz +0,1 % Phase error
between channels at same frequency <1°. Error correction system Double Encoded
Reed Solomon Code. Bit error rate better 10-10 Recording format Helical Scan
R-DAT Illuminated display with following indications: date/time - program ie.
test number - tape length counter for absolute time - program time - remaining
record time - indications for functions like record -forward - reverse - tape
loaded etc. Additional indications like battery level - error condensing water
Functional buttons on tape deck: FORWARD - REVERSE - PLAY - RECORD -STOP - PAUSE
- HOLD Remote controllable with TTL-level for START/REC - STOP or/and event
controllable with 1 event for blocs of 1 min Power supply DC 10 ... 32 V,
battery (Option) or mains 220 V +/-10 % AC (Option) 110V AC (Option) Power
requirement approximate 10 Watt Environmental conditions: Operating temperature
range -5 C° to + 45 °C Storage temperature range -20 °C to + 60 °C Relative
humidity 20 ... 80 % non condensing Vibration 5g Mil. Standard 810 C, Curve C
Shock 10g in all directions Size 157 x 90 x 65 mm without shock absorber Weight
1.3 kg without shock absorber 16 analog channels; input and output are connected
via BNC connectors Measuring range ~5 V with overload indication for each
channel Resolution 12 Bit, simultaneous sampling of all channels Input impedance
100 KOhm, SNR 72 dB Over voltage protection +40 V Total sampling rate 96 kHz,
distributed to selected number of channels ( see table ) 8-pole lowpass
Butterworth filter for input and output, avoiding Aliasing effects and smoothing
the output signals; damping in locking area 48 dB/Octave Analog output impedance
2 Ohme, max. 10 mA, +/-5V Programmable for 2 - 4 - 8 - 16 channel mode Signal
bandwidth max. in 2 channel mode 0 ... 16 kHz (-3dB) Serial Interface, suitable
for direct transmission even over long cables or for RF- or IR-transmission PC
Interface plug-in board for all IBM comp. PCs (Option) Digital pulse input
(TTL), that means pulses from 0 ... 20 kHz can be recorded and reproduced. Date
and time recording (year- month - day - hour - minute - second) Tape length
counter for absolute time, programming time, remaining record time. Automatic or
manual setting of test number Fast search run in both directions searching the
test number Remote control unit with bargraph display, Voice channel and
overload indication (option) Voice channel with external microphone and built-in
loudspeaker, signal bandwidth 60 ... 2800 Hz. Recording time 3 hours with a
DT180 cassette Storing capacity approximate, 2.4 Giga Byte with a DT180 cassette
Reproducible accuracy between record and replay at 0 Hz +0,1 % Phase error
between channels at same frequency <1°. Error correction system Double Encoded
Reed Solomon Code. Bit error rate better 10-10 Recording format Helical Scan
R-DAT Illuminated display with following indications: date/time - program i.e.
test number - tape length counter for absolute time - program time - remaining
record time - indications for functions like record -forward - reverse - tape
loaded etc. Additional indications like battery level - error condensing water
Functional buttons on tape deck: FORWARD - REVERSE - PLAY - RECORD -STOP - PAUSE
- HOLD Remote controllable with TTL-level for START/REC - STOP or/and event
controllable with 1 event for blocs of 1 min Power supply DC 10 ... 32 V,
battery (Option) or mains 220 V +/-10 % AC (Option) 110V AC (Option) Power
requirement approximate 10 Watt Environmental conditions: Operating temperature
range -5 C° to + 45 °C Storage temperature range -20 °C to + 60 °C Relative
humidity 20 ... 80 % non condensing Vibration 5g Mil. Standard 810 C, Curve C
Shock 10g in all directions Size 160 x 90 x 90 mm without shock absorber Weight
1.5 kg without shock absorber Table: Analogue bandwidth kHz -3 dB Scanning rate
kHz Channel Mux 2 CH. 4 CH. 2 CH. 4 CH. max. 3 hours 16 kHz 8 kHz 48 kHz 24 kHz
D-2/8 - Mobile mini DAT recorder Smallest 8 channel DAT recorder of world for
record and playback form analog signals up to 16 kHz per channel in 2 channel
mode. Record and reproduce of 8 analog data channels, voice, date, time and
digital signals. Extremely small and ruggedized design and therefore multiple
application areas Usable in each position and therefore especially suitable for
extreme mobile applications Very resistant against shock and vibrations
Extremely adaptable to various measuring requests due to switchable number of
channels and signal bandwidth Robust remote control box with bargraph display
Computer interface for on- and off-line Data analysis (OPT.) Telemetry
connection for computer interface for on-line data analysis during mobile use
(OPTION) Event-driven record commands Record commands by Remote Control
Automatic test number recording Fast search run in both directions Power supply
DC 10 ... 32 V, battery (OPTION), mains 220 V AC (OPTION) The D-2/8 DAT Recorder
is small and powerful. The physical size has a major advantage over larger units.
Due to the small mechanical dimension it can be. This becomes apparent, whenever
space or critical positioning is the issue. Good examples are the cramped
quarters of building and earth-moving machines, cars and planes. The
surveillance's and analysis is done On-line. A telemetry output, connected to
our RF telemetry TS/TE 2.5, transmits the data to a computer. Concurrently, high
redundancy recording of raw data takes place within the DAT. With the aid of our
REMUS Software all or single channels can be selected and/or presented. The
computer freed from the ''Data Logging" task can now be utilized for analysis
and presentation. The ''Record Commands" can be controlled remotely. The "Record
Procedure" is started and terminated with the +5 V and 0 V levels respectively.
Sometimes, especially during long term measurements, continuous recording would
be impractical. In this case the ''Event-Driven" record control is a powerful
tool. Supporting this feature is one "Event Channel". Once an ."Event Channel"
is activated, a ''Record Procedure'' of approximately 1 minute is started. This
procedure includes the recording of the active event, time and test number. The
D-2/8 DAT can convert data from analog to digital and feed them into computer
directly without recording. For this operation the "Tape Bypass" function is
used. Just as in recording mode the analog data are filtered and digitized. The
data are transferred directly to the computer instead to tape. This is
independent upon the tape runs and records data or stays without recording. In
this mode the DAT recorder is used as PCM encoder for telemetry transmission.
Another feature is the pulse input DIG In/Out. With that feature any pulses with
any sampling relationship from 0 to 20 kHz can be recorded and reproduced. This
input is very suitable for PCM signals transmitted via RF telemetry. Data from
PCM encoders, input pulses from sensors for revolution or speed, or the
recording of simple events are just a few. Optionally an event multiplexer for
16 events is available. These are some examples of the flexible use of our Data
Recorder D-2/8. For more information contact our sales office. References:
(D-2/16, D-2/8 and D-2/4) Aprilia motorcycle Italy Benetton Formula 1 England
CNES France MIR Space Sation Daewoo Corp. Korea Ferrari Formula 1 Italy Fiat
Italy Renault Sport France SAGEM France Samsung Heavy Industry Korea Hyundai
Korea Military test departments Railway Germany VW Brazil and many more .... .
Applikation pictures Missile (D-2/16) Missile (D-2/4) MIR Space Station (D-2/8
Spec.) CNES France Technical data: 8 analog channels; input and output are
connected via BNC connectors Measuring range +/-5 V with overload indication for
each channel Resolution 12 Bit, simultaneous sampling of all channels Input
impedance 100 KOhm, SNR 72 dB Over voltage protection +40 V Total sampling rate
96 kHz, distributed to selected number of channels ( see table ) 8-pole lowpass
Butterworth filter for input and output, avoiding Aliasing effects and smoothing
the output signals; damping in locking area 48 dB/Octave Analog output impedance
2 Ohme, max. 10 mA, +/-5V Programmable for 2 - 4 - 8 channel mode Signal
bandwidth max. in 2 channel mode 0 ... 16 kHz (-3dB) Serial Interface, suitable
for direct transmission even over long cables or for RF- or IR-transmission PC
Interface plug-in board for all IBM comp. PCs (Option) Digital pulse input
(TTL), that means pulses from 0 ... 20 kHz can be recorded and reproduced. Date
and time recording (year- month - day - hour - minute - second) Tape length
counter for absolute time, programming time, remaining record time. Automatic or
manual setting of test number Fast search run in both directions searching the
test number Remote control unit with bargraph display, Voice channel and
overload indication (option) Voice channel with external microphone and built-in
loudspeaker, signal bandwidth 60 ... 2800 Hz. Recording time 3 hours with a
DT180 cassette Storing capacity approximate, 2.4 Giga Byte with a DT180 cassette
Reproducible accuracy between record and replay at 0 Hz +0,1 % Phase error
between channels at same frequency <1°. Error correction system Double Encoded
Reed Solomon Code. Bit error rate better 10-10 Recording format Helical Scan
R-DAT Illuminated display with following indications: date/time - program i.e.
test number - tape length counter for absolute time - program time - remaining
record time - indications for functions like record -forward - reverse - tape
loaded etc. Additional indications like battery level - error condensing water
Functional buttons on tape deck: FORWARD - REVERSE - PLAY - RECORD -STOP - PAUSE
- HOLD Remote controllable with TTL-level for START/REC - STOP or/and event
controllable with 1 event for blocs of 1 min Power supply DC 10 ... 32 V,
battery (Option) or mains 220 V +/-10 % AC (Option) 110V AC (Option) Power
requirement approximate 10 Watt Environmental conditions: Operating temperature
range -5 C° to + 45 °C Storage temperature range -20 °C to + 60 °C Relative
humidity 20 ... 80 % non condensing Vibration 5g Mil. Standard 810 C, Curve C
Shock 10g in all directions Size 160 x 90 x 90 mm without shock absorber Weight
1.5 kg without shock absorber Table: Analogue bandwidth kHz -3 dB Scanning rate
kHz Channel Mux 2 Ch. 4 Ch. 8 Ch. 2 Ch. 4 Ch. 8 Ch. max. 3 hours 16 kHz 8 kHz 4
kHz 48 kHz 24 kHz 12 kHz D-2/16 - Mobile mini DAT recorder A small device for
extremely hard applications Smallest 16 channel DAT recorder of the world for
record and playback of analog signals up to 16 kHz per channel Record and
reproduce of 16 analog data channels, voice, date, time and digital signals.
Extremely small and ruggedized design and therefore multiple application areas
Usable in each position and therefore especially suitable for extreme mobile
applications Very resistant against shock and vibrations Extremely adaptable to
various measuring requests due to switchable number of channels and signal
bandwidth Robust remote control box with bargraph display Computer interface for
on- and off-line Data analysis (OPT.) Telemetry connection for computer
interface for on-line data analysis during mobile use (OPTION) Event-driven
record commands Record commands by Remote Control Automatic test number
recording Fast search run in both directions Power supply DC 10 ... 32 V,
battery (OPTION), mains 220 V AC (OPTION) The D-2/16 DAT Recorder is small and
powerful. The physical size has a major advantage over larger units. Due to the
small mechanical dimension it can be. This becomes apparent, whenever space or
critical positioning is the issue. Good examples are the cramped quarters of
building and earth-moving machines, cars and planes. The surveillance's and
analysis is done On-line. A telemetry output, connected to our RF telemetry
TS/TE 2.5, transmits the data to a computer. Concurrently, high redundancy
recording of raw data takes place within the DAT. With the aid of our REMUS
Software all or single channels can be selected and/or presented. The computer
freed from the ''Data Logging" task can now be utilized for analysis and
presentation. The ''Record Commands" can be controlled remotely. The "Record
Procedure" is started and terminated with the +5 V and 0 V levels respectively.
Sometimes, especially during long term measurements, continuous recording would
be impractical. In this case the ''Event-Driven" record control is a powerful
tool. Supporting this feature is one "Event Channel". Once an ."Event Channel"
is activated, a ''Record Procedure'' of approximately 1 minute is started. This
procedure includes the recording of the active event, time and test number. The
D-2/16 DAT can convert data from analog to digital and feed them into computer
directly without recording. For this operation the "Tape Bypass" function is
used. Just as in recording mode the analog data are filtered and digitized. The
data are transferred directly to the computer instead to tape. This is
independent upon the tape runs and records data or stays without recording. In
this mode the DAT recorder is used as PCM encoder for telemetry transmission.
Another feature is the pulse input DIG In/Out. With that feature any pulses with
any sampling relationship from 0 to 20 kHz can be recorded and reproduced. This
input is very suitable for PCM signals transmitted via RF telemetry. Data from
PCM encoders, input pulses from sensors for revolution or speed, or the
recording of simple events are just a few. Optionally an event multiplexer for
16 events is available. These are some examples of the flexible use of our Data
Recorder D-2/16. For more information contact our sales office. References:
(D-2/16 and D-2/4) Aprilia motorcycle Italy Benetton Formula 1 England CNES
France MIR Space Sation Daewoo Corp. Korea Ferrari Formula 1 Italy Fiat Italy
Renault Sport France SAGEM France Samsung Heavy Industry Korea Hyundai Korea
Military test departments Railway Germany VW Brazil and many more .... .
References: (D-2/16, D-2/8 and D-2/4) Missile (D-2/16) Missile (D-2/4) MIR Space
Station (D-2/8 Spec.) CNES France Technical data: 16 analog channels; input and
output are connected via BNC connectors Measuring range +/-5 V with overload
indication for each channel Resolution 12 Bit, simultaneous sampling of all
channels Input impedance 100 KOhm, SNR 72 dB Over voltage protection +40 V Total
sampling rate 96 kHz, distributed to selected number of channels ( see table )
8-pole lowpass Butterworth filter for input and output, avoiding Aliasing
effects and smoothing the output signals; damping in locking area 48 dB/Octave
Analog output impedance 2 Ohme, max. 10 mA, +/-5V Programmable for 2 - 4 - 8 -
16 channel mode Signal bandwidth max. in 2 channel mode 0 ... 16 kHz (-3dB)
Serial Interface, suitable for direct transmission even over long cables or for
RF- or IR-transmission PC Interface plug-in board for all IBM comp. PCs (Option)
Digital pulse input (TTL), that means pulses from 0 ... 20 kHz can be recorded
and reproduced. Date and time recording (year- month - day - hour - minute -
second) Tape length counter for absolute time, programming time, remaining
record time. Automatic or manual setting of test number Fast search run in both
directions searching the test number Remote control unit with bargraph display,
Voice channel and overload indication (option) Voice channel with external
microphone and built-in loudspeaker, signal bandwidth 60 ... 2800 Hz. Recording
time 3 hours with a DT180 cassette Storing capacity approximate, 2.4 Giga Byte
with a DT180 cassette Reproducible accuracy between record and replay at 0 Hz
+0,1 % Phase error between channels at same frequency <1°. Error correction
system Double Encoded Reed Solomon Code. Bit error rate better 10-10 Recording
format Helical Scan R-DAT Illuminated display with following indications:
date/time - program i.e. test number - tape length counter for absolute time -
program time - remaining record time - indications for functions like record
-forward - reverse - tape loaded etc. Additional indications like battery level
- error condensing water Functional buttons on tape deck: FORWARD - REVERSE -
PLAY - RECORD -STOP - PAUSE - HOLD Remote controllable with TTL-level for START/REC
- STOP or/and event controllable with 1 event for blocs of 1 min Power supply DC
10 ... 32 V, battery (Option) or mains 220 V +/-10 % AC (Option) 110V AC
(Option) Power requirement approximate 10 Watt Environmental conditions:
Operating temperature range -5 C° to + 45 °C Storage temperature range -20 °C to
+ 60 °C Relative humidity 20 ... 80 % non condensing Vibration 5g Mil. Standard
810 C, Curve C Shock 10g in all directions Size 160 x 90 x 90 mm without shock
absorber Weight 1.5 kg without shock absorber Table: Analogue bandwidth kHz -3
dB Scanning rate kHz Channel Mux 2 Ch. 4 Ch. 8 Ch. 16 Ch. 2 Ch. 4 Ch. 8 Ch. 16
Ch. max. 3 hours 16 kHz 8 kHz 4 kHz 2 kHz 48 kHz 24 kHz 12 kHz 6 kHz DA-PCM HS
High speed PCM recorder up to 1280 kbit/s Bit rate 80 ... 1280 kHz (TTL level)
Voice channel for commends Recording & reproducing from modulated IRIG B time
code (Opt. instead voice CH.) Recording time 120 minutes Error correction
(Double encoded Reed Solomon Code) Weight 1000 grams Very resistant again shock
(10g) and vibrations (5g) Small size (160 x 85 x 65 mm) Power 10...30 V DC, 8
Watt DA-PCM HS recorder is a special development only for record and replay of
PCM coded data streams, with additive speech comments or IRIG B time code. First
mode: The most flexible method is available when PCM data and a pulse clock are
present at the encoder. In this case each different PCM coded data can be
recorded and reproduced with a data rate of 80 up to 1280 kbit/s. Second mode:
(OPTION) When only the PCM coded data without clock is provided form the encoder,
record an replay is only possible with a corresponding option. In this case is
only one bit rate for a special PCM code possible. Please inform us about the
desired bit rate and PCM code when order. Bit rate: The maximum bit rate of 1280
kbit/s is only possible, if the bit rate and the clock have the same frequency.
For some PCM codes such as e. g. Miller code the double clock rate is limited to
a maximum of 640 kbit/s. This fact also concern mode one and two.Record of
speech and IRIG B time code information. Independent of the measured data (PCM
data), speech or IRIG B time code information can be recorded. (Please fix your
choice when order, because only one mode can be installed). IRIG B time code
will be only recorded and replayed in a modulated format. A display for IRIG B
time on the recorder is not available. Remote control Additive to the normal DAT
recorder handling buttons, there is an input for record start/ duration
available. Via opto coupler (galvanic isolation) the pulse width (with a
potential of 5 up to 30 V) start and regulate the duration . The pulse must have
a potential of 5 up to 30 V) Tape deck function Record - Play - Stop - Pause -
Fast forward - Fast reverse Technical data's: Bitrate: With available clock and
PCM 80 ... 1280 kbit/s Without clock:: (Option) PCM only 1 bit rate between 80
... 1280 kbit/s, Miller code only 1 bit rate max. 640 kbit/s Level: TTL Clock
generator: Only, if not present a clock signal for recording PCM code(Option)
Input impedance: 100 k ohme Output impedance: 10 ohme , max 10 mA Remaining
jitter: max. 1% Voice channel: 400-3000 Hz, resolution 8 bit IRIG B time code:
modulated input/output without display (Option) (instead of voice channel) Event
marker: 1 ... 99, automatic start of recording Internal Clock: year - month -
day - hour - min. - sec. (absolute time and recording time) Remote control:
Start recording/Stop via 5 .. 30 V DC level Remote control box: Record - Play -
Stop - Pause (Option) Tape deck: Cassette "DAT format (Digital Audio Tape)" Tape
counter: 0 ... 120 min, resolution 1 sec. recorded time and remaining time
display Recording time 2 hours with DT 120 cassettes Recording format Helical
scan recording DAT format Error correction Double encoded Reed Solomon Code
Environmental: Vibration 5g - Std 810C curve C Acceleration 10g - all directions
Operating temp. -10°C ... +45°C Storage temp. -20°C ... +60°C Power: 10 ... 30 V
DC, 6 Watt Size: 160 x 85 x 65 mm Weight: 1000 grams We are manufacturer of
Measuring & PCM tape recorder, PCM telemetry system, -signal conditioning,
measuring notebook up to 64 CH. Our customers are research and test departments
in the automotive, racing sport, military area, aviation and aerospace area.
Telemetry Systems CT8 New ( optional 16 channels ) Compact Telemetry System with
8 channels, direct Sensor connection · 8 channels, 12 bit resolution,
simultaneous sampling of all channels · Anti aliasing filters · Direct sensor
connection for STG, Thermo couples K or high level inputs · +/- 5V analogue
output at the receiver side, optional dig. output for PC interface · Distance up
to 500m between transmitter and receiver · Static acceleration up to 100 g in
all directions · Signal bandwidth 8 x 0-95 Hz with 40kbit transmitter, 8 x 0-750
Hz with 320kbit transmitter CT2-Mini New Small Telemetry System with 2 channels,
direct Sensor connection · 2 channels, 12 bit resolution, simultaneous sampling
of all channels · Anti aliasing filters · Direct sensor connection for STG,
Thermo couples K or high level inputs · +/- 5V analogue output at the receiver
side, optional dig. output for PC interface · Distance up to 500m between
transmitter and receiver · Static acceleration up to 100 g in all directions ·
Signal bandwidth 2 x 0-375Hz with 40kbit transmitter CT4-Wheel New ( optional 8
channels ) 4 (8) Channel wheel telemetry system for connection with strain gages,
force, temperature and vibration sensors as well as high level input +/-5 or
+/-10Volts. · 4 different carrier frequencies (433.3, 433.7, 434.1 or 434.5 MHz)
enable measurements at 4 Wheels for one car. · A mixed installation of different
signal conditioning modules possible. · Universal mounting adapter enables a
fast and exactly montage on different kind of wheels. · The transmitting system
is dust and water protected (IP65). CT8-Rotate New Telemetry system for rotating
Applications · Direct sensor connection for STG, TH K, ICP and High level inputs
(+/-5V or +/-10V) · Signal bandwidth 8 x 0...95Hz · Integrated Battery (Akku)
for up to 6 hours operating time · Digital transmitting in 4 different carrier
frequencies (433.3, 433.7, 434.1 or 434.5 MHz) enables up to 4 CT8-Rotate
telemetry system can work parallel at the same time. · Waterproofed housing
(IP65) MT32 New Mini Telemetry System up to 32 channels, direct Sensor
connection · 12 bit resolution, simultaneous sampling of all channels · Anti
aliasing filters · Direct sensor connection for STG, Thermo couples K and ICP
sensors · +/- 5V analogue output at the receiver side, optional dig. output for
PC interface · Different transfer possibilities like IR- or RF- transmission for
short and long distance · Small module design to solve a lot of different
applications · Powering transmitting side via battery or inductive TEL 32/16/8
Telemetry Digital telemetry system for 32 channels Fixed Signal bandwidth 32x
800Hz / channel with 2,45 GHz Transmitter - 1,28 Mbit/s or Fixed Signal
bandwidth 32x 200Hz / channel with 433 MHz Transmitter - 320 kbit/s or Fixed
Signal bandwidth 32x 25Hz / channel with 433 GHz Transmitter - 40 kbit/s Digital
telemetry system for 16 channels Fixed Signal bandwidth 16x 1600Hz / channel
with 2,45 GHz Transmitter - 1,28 Mbit/s or Fixed Signal bandwidth 16x 400Hz /
channel with 433 MHz Transmitter - 320 kbit/s or Fixed Signal bandwidth 16x 50Hz
/ channel with 433 GHz Transmitter - 40 kbit/s Digital telemetry system for 8
channels Fixed Signal bandwidth 8x 3200Hz / channel with 2,45 GHz Transmitter -
1,28 Mbit/s or Fixed Signal bandwidth 8x 800Hz / channel with 433 MHz
Transmitter - 320 kbit/s or Fixed Signal bandwidth 8x 100Hz / channel with 433
GHz Transmitter - 40 kbit/s Simultane samling, 12 bit resolution, Anit- Aliasing
filter 8. order. Butterworth, Distance up to 500m free view (more distance on
request) Optional 64 or 128 channels avalable! PCM 4 Telemetrie (special) 4
Channel mini telemetry system with analogue and digital output, 2.45 GHz
transmission frequency, 20mW transmittion power for distance up to 500 meters.
Signal bandwidth up to 10000 Hz in 2 Channel Mode PCM 16 Telemetrie (special) 16
Channel mini telemetry system with analogue and digital output, 2.45 GHz
transmission frequency, 20mW transmittion power for distance up to 500 meters.)
Signal bandwidth up to 10000 Hz in 2 Channel Mode TEL1/40k TTL 1 channel TTL
telemetry to transmit from 40 TTL pulses/s up to TTL 40000 pulses/s TEL1-FM New
One channel telemetry system for rotating applications, signal bandwidth up to
10kHz. RTSE600 1 Channel mini telemetry system incl. signal conditioning for STG,
LVDT, Th, ICP Analogue output +/-5V, Signal bandwidth 600 Hz, 433 MHz
transmission frequency, 10mW transmisson power, distance up to 250 meters
Comfortable 4 channel mini telemetry system with analogue and digital output,
2.45 GHz transmission frequency with 20mW transmitter for distance up to 500
meters. 4 channels (2-4 channel mode) Analogue signal bandwidth 0 Hz-10 kHz/channel
(2 ch. mode) 80 kHz total scanning rate (2.45 GHz transmitter) 12 bit resolution
Simulation scanning rate to all selected channel Anti-aliasing filters Distance
up to 500m - more on request HF transmitter 2.45 GHz 20mW or (433.9 MHz 10mW)
Dimensions encoder 150x65x80mm, decoder 160x65x80mm Power 10...32 V DC, 6 Watt
Technical datas Encoder - PCM4-1.28 ENC. Input 4 channels via BNC Input
impedance 100KW, +/-5V Overload indicators, Resolution 12 bit Amplitude dynamic
72 dB Signal to noise ratio 60 dB Simulation scanning rate to all selected
channel Channel mux 4-2, Total scanning rate, selectable by jumper 10-20-50-80
kHz Anti-aliasing filters with low pass, 8. order Butterworth, 48dB/Octave
Analogue signal bandwidth see table Linearity 0,2%, Output PCM, bitrate
160-320-640-1280 kbit/s, with additional NRZ and clock HF transmitter 433.9 MHz,
10mW, mod. bandwidth 160-320 kbit/s FM modulated (OPTION) or HF transmitter 2.45
GHz, 20mW, mod. bandwidth 160-1280 kbit/s FM modulated (OPTION) Power 10-32 V
DC, 6 Watt Dimensions 150 x 65 x 80mm Weight 800 grams Decoder - PCM4-1.28 DEC.
Input RF 433.9 MHz or 2.45 GHz FM modulated (OPTION) Modulation bandwidth
160-320 kbit/s for RF 433.9 MHz PCM - NRZ and clock or 160-1280 kbit/s for RF
2.45 GHz, PCM - NRZ and clock Output 4x +/-5V via BNC mini connectors, impedance
2kW, max. 10mA Simulation out Resolution 12 bit, dynamic range 72 dB, 8. order
Butterworth low pass filter for smoothing, Signal noise ratio 60 dB, Linearity
0,2%, Analogue signal bandwidth see table Digital output: PCM - NRZ and clock,
computer interface Power 10...32 V DC, 6 Watt Dimensions 160 x 65 x 80mm Weight
900 grams System environments (encoder/decoder) Vibration 20g Mil Std. 810 E
Acceleration 100g in all directions Shock 100g Humidity 20-80% non condensing
Operating temperature -20°C ...+60°C A multiple-channel mini telemetry system
for data acquisition and non-contact data transmission from rotating or moving
parts. Up to 16 measuring channels, 4 channels max. in one module. Mixed
installation practicable, also inside one module: STG, LVDT, Thermocouple J+K
.... . Programmable via an interactive "Remote Control Box" with display. The
set-up is stored in a non volatile memory Power supply: batteries, inductive or
slip rings. Total sampling rate 750 Hz up to 12 000 Hz. Resolution 12 Bit
Simultaneous sampling of all channels (S&H) Automatic switchable antialiasing
filters (8 order Butterworth) Water and shock proof system design Analogue and
digital signal outputs (receiver module) as well as PC interface and analysing
software available (OPTION). The RT8/16 Rotate telemetry system was specially
developed for data acquisition on rotating or moving parts. To avoid expensive
and complicated slip rings as well as noise problems, we recommend RT8/16 Rotate.
By using non contact digital ( PCM ) RF transmission, an excellent transmission,
also under very rough conditions, without any noise problem is guaranteed. A
typical application could be to measure torsion and vibration on the rotor /
blades of a helicopter , aircraft, wind power plants or a turbine as well as
wheel measurements. Further applications could be data acquisition on rotating
or moving parts on agricultural and earth moving machines. Transmitter No. of
channels: max. 16, in 4-channel steps extendible. Adaptable sensors: all common
sensors for vibration, force, temperature, displacement. Installation: mixed
installation ( in steps of one) inside the 4 channel housing allowed, modules
for strain gauge, displacement, vibration, shock, temperature available
Programming: Type of sensor, excitation, gain, auto zero, sampling rate.all menu
guided via an interactive remote control box. The set-up is stored in an non
volatile memory to enable easy parameter setting without disassembling the
system. Power supply: Batteries, inductive or via available slip rings. Signal
transmission: Digital in PCM-format via RF radio telemetry Mechanic: Water and
shock proof system design Receiver stationary Output: Up to 8 (16) analogue
cannel’s via BNC ± 5V and digital for direct PC-input with our interface card
and transfer software (OPTION). A digital and analogue record / replay with a
DAT recorder is also possible. (Please regard to our different DAT recorders.)
Power supply: DC 10 ... 18V Technical datas Transmitter: Transmitter module No.
of channels: Max. 16, in 4-channel steps extendible Filter: Low pass, 8 order
Butterworth Sampling: Simultaneous for all channels(S&H) Sampling rate: 750 Hz
...12 kHz total , to divide by No. of channels Resolution: 12 Bit Signal to
noise ratio: 60 dB Amplitude dynamics: 72 dB Analogue signal bandwidth in 160
kbit/s mode: 1-channel mode 0...3000 Hz (-3dB) 2-channel mode 0...1500 Hz (-3d
B) 4-channel mode 0...750 Hz (-3d B) 8-channel mode 0...375 Hz (-3dB) 16-channel
mode 0...188 Hz (-3dB) the band width above correspond to the digital output. At
the analogue output the cut-off frequency is -6dB depending on one further
filtering. PCM: According to DIN 66224 RF-frequency: 433,9 MHz Modulation: FSK
Bit rate: 10-20-40-80-160 kbit/s RF transmission power : 10 mW Range of
transmission: 200 ... 500m General: Each ring (input module) has space for up to
4 channels. It can also be equipped with different signal conditioning modules.
It makes the system flexible and you can optimise it in order to fulfill all
measurement requirements. RPM: Depending on sort of connectors 360-6000 RPM
Weight: 4 channels 2,0 kg ( without power supply ) 8 channels 2,5 kg (without
power supply ) Size: Dimensions in 4 channel mode Ø 125 x 125 without mounting
plate Dimensions in 8 channel mode Ø 125 x 150 without mounting plate The
housing can be designed for customer specifications ! Technical data Receiver:
No. of channels: max 16 Output Digital: for computer interface (IBM compatible
PC) Software for transmission and analysing OPTIONAL Output analog: max. 8 (16)
analogue, range ± 5V RF-frequency: 433,9 MHz Modulation: FSK Bit rate: max. 160
kbit/s Dimensions: 210 x 110 x 90 mm Power supply: 10...18V DC Technical data
sensor module STG (Strain gauge): all settings made from the remote control box
: ½ and 1/1 bridge 350 Ohme or more Bridge excitation 2-4-8V (± 0,2%) Gain 2 - 4
- 10 - 20 - 40 - 100 - 200 - 400 - 1000 - 2000 Auto zero ± 0,2% CMR: V=1000 =
90dB Linearity error: V 1-100 = 0,1% V 200 = 0,2% V 300 = 0,3% V 1000 = 0,5%
LVDT Only inductive sensors, not suitable for STG Carrier frequency: 5 kHz
Amplitude: 10V Analogue signal band width: 0...400 Hz Gain: 1-2-5-10 Th
Thermocouple J+K (specify when order) Output: 10mV/'C moment of inertia and
weight like series one without residual torque, contactless transmission very
easy to mount universal usable for all typs of passenger-cars automatic
adjustment of all components high accurasy, selectable signalfrequency
integrated powersupply small and compact reproducer For more information, pls.
down load PDF data sheet Shock-proof 10.000 g High long-term stability Housing
hermetically sealed True DC-response Very low temperature drift No signal
hysteresis Very integrated sensor electronics Extremely low power consumption
Signal conditioning modules with 3 measuring ranges per accelerometer available
The Capacitive Accelerometers measure the acceleration, vibration and the
inclination of any object. Due to adequate handling of generated measurement
information either direction and rate of an acceleration vector or the velocity
and covered distance of the test object can be determined. B1, B2 and B3 are
capacitive accelerometers with an integrated circuit for transforming the
capacitive response into an analog DC signal. The accelerometers are designed
for acceleration measurements of vehicles, machines, buildings and plants as
well as for seismic, dynamic, inclination and vibration measurements. They also
guarantee for fast diagnosis of errors and are extraordinarily appropriated for
stress control at strained components. The applied measuring system is based
upon a gas-dynamical damped spring-mass-system as a part of a capacitive primary
converter. With our special developed signal conditioning modules (SC-4/M,
MC16/64 and RTSE600) it is possible to make a 3-stage full scale calibration by
switching the gain, e.g. a 50g sensor with measuring ranges of 5g, 20g and 50g.
The offset based on the earth gravitation may easy be compensated to a 0 volt
output using the auto-zeroing function or a variable resistor. Model B1 B2 B3
Range: ± 3 g ± 10 g ± 50 g Resolution: 10 -3 g 10 -2 g 10 -1 g Sensitivity: ca.
110 mV/g ca. 23 mV/g ca. 6,5 mV/g Non-linearity: < 1 % FS < 1 % FS < 1 % FS
Transverse sensitivity: < 1 % FS < 1 % FS < 1 % FS Measuring frequency: 0-160 Hz
0-350 Hz 0-550 Hz Thermal zero shift: < 0,1 mV/K < 0,1 mV/K < 0,1 mV/K Thermal
sensitivity shift: + 6× 10 -4 /K + 6× 10 -4 /K + 6× 10 -4 /K Supply voltage,
stabilized: 5 VDC 5 VDC 5 VDC Zero-point (offset): + 2,5 ± 0,1 V + 2,5 ± 0,1 V +
2,5 ± 0,1 V Quiescent current: appr. 1mA appr. 1mA appr. 1mA Mechanical shock:
10.000g ! 10.000g ! 10.000g ! IP ratings: IP 65 IP 65 IP 65 Operating
temperature range: - 40 ° C ... + 85 ° C - 40 ° C ... + 85 ° C - 40 ° C ... + 85
° C Storage temperature range: - 45 ° C ... + 90 ° C - 45 ° C ... + 90 ° C - 45
° C ... + 90 ° C Dimensions: 36 x 24 x 13 mm 36 x 24 x 13 mm 36 x 24 x 13 mm
Weight: 45 gram 45 gram 45 gram Housing: anodized aluminum anodized aluminum
anodized aluminum Electrical connection: 4-pole male Lemosa 4-pole male Lemosa
4-pole male Lemosa